LOCA_ID |
|
ID |
327-16A |
Location identifier |
SAMP_TOP |
m |
2DP |
24.55 |
Depth to top of sample |
SAMP_REF |
|
X |
24 |
Sample reference |
SAMP_TYPE |
|
PA |
U |
Sample type |
SAMP_ID |
|
ID |
ABC121415010 |
Sample unique global identifier |
SPEC_REF |
|
X |
1a |
Specimen reference |
SPEC_DPTH |
m |
2DP |
24.55 |
Depth to top of test specimen |
SPEC_DESC |
|
X |
Grey angular limestone |
Specimen description |
SPEC_PREP |
|
X |
Prepared according to client instructions |
Details of specimen preparation including time between preparation and testing |
ASDI_SDI1 |
% |
1DP |
6.1 |
First cycle slake durability index (if ASDI_SDI1 or ASDI_SDI2 is between 0% and 10%) |
ASDI_SDI2 |
% |
1DP |
8.6 |
Second cycle slake durability index |
ASDI_SOLN |
|
X |
Tap water at 20 degC |
Nature and temperature of slaking fluid |
ASDI_INDR |
|
X |
All fragments showing partial disintegration |
Appearance of fragments retained in the drum |
ASDI_PADR |
|
X |
Fine particles in suspension with thin layer of larger particles in base of trough. |
Appearance of fragments passing through the drum |
ASDI_REM |
|
X |
|
Remarks |
ASDI_METH |
|
X |
ISRM : Suggested method for determining slake durability index. |
Test method |
ASDI_LAB |
|
X |
ACME Laboratories plc |
Name of testing laboratory/organisation |
ASDI_CRED |
|
X |
UKAS 0000 |
Accrediting body and reference number (when appropriate) |
TEST_STAT |
|
X |
Checked |
Test status |
FILE_FSET |
|
X |
FS10 |
Associated file reference (eg test result sheets) |