IFID: On Site Volatile Headspace Testing Using Flame Ionisation Detector

  • Class: Samples, Amalgamated Specimens and Laboratory Test Scheduling
Heading Unit Type Example Description
LOCA_ID   ID 327-16A Location identifier
IFID_DPTH m 2DP 1 Depth of headspace test sample
IFID_TESN   X 2 Test reference
IFID_DATE yyyy-mm-dd DT 20/02/2003 Test date
IFID_RES ppmv 0DP 10 Result of FID analysis
IFID_REM   X   Remarks on test
IFID_ENV   X Misty Details of weather and environmental conditions during test
IFID_METH   X Flame ionisation detector Details of FID used and method description
IFID_CONT   X ACME On-site Testing Ltd Name of testing organisation
IFID_CRED   X UKAS 0000 Accrediting body and reference number (when appropriate)
TEST_STAT   X Checked Test status
GEOL_STAT   X 1 Stratum reference shown on trial pit or traverse sketch
FILE_FSET   X FS23 Associated file reference (eg test result sheets)

Notes - 2

  • IFID is used to record the results of on site volatile testing by means of headspace analysis using flame ionisation detectors.
  • IFID_CRED added to permit details of any test accreditation if appropriate to be included in data.