IPID: On Site Volatile Headspace Testing by Photo Ionisation Detector

  • Class: Samples, Amalgamated Specimens and Laboratory Test Scheduling
Heading Unit Type Example Description
LOCA_ID   ID 327-16A Location identifier
IPID_DPTH m 2DP 1 Depth of headspace test sample
IPID_TESN   X 3 Test reference
IPID_DATE yyyy-mm-dd DT 20/02/2003 Test date
IPID_TEMP degC 1DP 15.1 Ambient temperature at time of test
IPID_RES ppmv 2DP 10 Result of PID analysis
IPID_REM   X   Remarks on test
IPID_ENV   X Cloudy with light rain Details of weather and environmental conditions during test
IPID_METH   X Carried out on temporary samples using photo ionisation detector fitted with 10.6 eV lamp Details of PID used and method description
IPID_CONT   X ACME On-site Testing Ltd Name of testing organisation
IPID_CRED   X UKAS 0000 Accrediting body and reference number (when appropriate)
TEST_STAT   X Checked Test status
GEOL_STAT   X 1 Stratum reference shown on trial pit or traverse sketch
FILE_FSET   X FS45 Associated file reference (eg test result sheets)

Notes - 3

  • IPID is used to record the results of on site volatile testing by means of headspace analysis using photo ionisation detectors.
  • IPID_CRED added to permit details of any test accreditation if appropriate to be included in data.
  • Clause 7.9.8 of the updated SISG Specification advises ambient weather and temperature to be recorded at time of test. IPID_ENV and IPID_TEMP added to include this information.