LOCA_ID |
|
ID |
327-16A |
Location identifier |
SAMP_TOP |
m |
2DP |
24.55 |
Depth to top of sample |
SAMP_REF |
|
X |
24 |
Sample reference |
SAMP_TYPE |
|
PA |
U |
Sample type |
SAMP_ID |
|
ID |
ABC121415010 |
Sample unique global identifier |
SPEC_REF |
|
X |
1a |
Specimen reference |
SPEC_DPTH |
m |
2DP |
24.55 |
Depth to top of test specimen |
SPEC_DESC |
|
X |
Grey slightly gravelly clay |
Specimen description |
SPEC_PREP |
|
X |
Prepared according to client instructions |
Details of specimen preparation including time between preparation and testing |
ESCG_TYPE |
|
PA |
CD |
Test type |
ESCG_CELL |
|
X |
250mm dia Hydraulic cell |
Type of equipment used |
ESCG_COND |
|
PA |
Undisturbed |
Sample condition |
ESCG_SDIA |
mm |
2DP |
100.15 |
Test specimen diameter |
ESCG_HIGT |
mm |
2DP |
100.25 |
Test specimen height |
ESCG_MCI |
% |
MC |
21 |
Initial moisture content |
ESCG_MCF |
% |
MC |
18 |
Final moisture content |
ESCG_BDEN |
Mg/m3 |
2DP |
2.12 |
Initial bulk density |
ESCG_BDEF |
Mg/m3 |
2DP |
2.2 |
Final bulk density |
ESCG_DDEN |
Mg/m3 |
2DP |
1.75 |
Initial dry density |
ESCG_PDEN |
Mg/m3 |
XN |
#2.65 |
Particle density with prefix # if value assumed |
ESCG_IVR |
|
3DP |
0.812 |
Initial voids ratio |
ESCG_SATR |
% |
0DP |
98 |
Initial degree of saturation |
ESCG_LOAD |
|
X |
Equal, Free, triaxial |
Type of loading ( strain ) |
ESCG_DRAG |
|
X |
To top, both ends, radial inwards, radial outwards |
Type of drainage |
ESCG_PPM |
|
X |
Centre base, offset |
Pore pressure measurement location |
ESCG_SPRS |
kPa |
2SF |
100 |
Swelling pressure, if measured |
ESCG_SATM |
|
X |
Back pressure, cell only, water permeation |
Method of saturation |
ESCG_SINC |
kPa |
0DP |
50 |
Saturation increments |
ESCG_SDIF |
kPa |
0DP |
10 |
Differential pressure during saturation |
ESCG_CELF |
kPa |
0DP |
310 |
Cell or diaphragm pressure at end of saturation |
ESCG_BACF |
kPa |
0DP |
300 |
Back pressure at end of saturation |
ESCG_BVAL |
|
2DP |
0.96 |
B value at end of saturation |
ESCG_SVOL |
ml |
1DP |
10 |
Volume of water taken in during saturation |
ESCG_REM |
|
X |
Sample from base of U100 sample, axis vertical |
Remarks including commentary on effect of specimen disturbance on test result |
ESCG_METH |
|
X |
BS1377, part 6, cl 5 |
Test method |
ESCG_LAB |
|
X |
ACME Laboratories plc |
Name of testing laboratory/organisation |
ESCG_CRED |
|
X |
UKAS 0000 |
Accrediting body and reference number (when appropriate) |
TEST_STAT |
|
X |
Checked |
Test status |
FILE_FSET |
|
X |
FS9 |
Associated file reference (eg equipment calibrations) |