ESCT: Effective Stress Consolidation Tests - Data

  • Class: Samples, Amalgamated Specimens and Laboratory Test Scheduling
Heading Unit Type Example Description
LOCA_ID   ID 327-16A Location identifier
SAMP_TOP m 2DP 24.55 Depth to top of sample
SAMP_REF   X 24 Sample reference
SAMP_TYPE   PA U Sample type
SAMP_ID   ID ABC121415010 Sample unique global identifier
SPEC_REF   X 1a Specimen reference
SPEC_DPTH m 2DP 24.55 Depth to top of test specimen
ESCT_INCN   X 3 Consolidation stage number
ESCT_REM   X Stage terminated at 90% pwp dissipation Additional stage specific details
ESCT_INCC kPa 0DP 600 Cell or diaphragm pressure applied during stage
ESCT_INCB kPa 0DP 300 Back pressure applied during stage
ESCT_PWP0 kPa 0DP 580 Pore pressure at end of undrained loading
ESCT_PWPF kPa 0DP 300 Pore pressure at end of consolidation stage
ESCT_INCF kPa 0DP 310 Effective stress at end of consolidation stage
ESCT_VR0   3DP 0.801 Voids ratio at start of increment
ESCT_VRE   3DP 0.621 Voids ratio at end of stress increment
ESCT_DISS % 0DP 98 Percentage pore pressure dissipation at end of stage
ESCT_DSET mm 3DP 0.234 Settlement measured during consolidation stage
ESCT_DVOL ml 1DP 22.1 Volume change measured during consolidation stage
ESCT_INMV m2/MN 2SF 0.32 Reported coefficient of volume compressibility over stress increment
ESCT_INCV m2/yr 2SF 4.1 Reported coefficient of consolidation over stress increment
ESCT_INSC   2SF 0.12 Coefficient of secondary compression over stress increment
ESCT_CVME   X Log time PWP, root time settlement Method used for deriving Cv
ESCT_TEMP degC 1DP 22 Average temperature over stress increment
FILE_FSET   X FS9 Associated file reference (eg test result sheets)

Notes - 1

  • ESCT_DVOL - consolidation (flow of water out of specimen) to be reported as positive and dilatancy or swelling (flow of water into specimen) to be reported as negative.