LDEN: Density Tests

  • Class: Samples, Amalgamated Specimens and Laboratory Test Scheduling
Heading Unit Type Example Description
LOCA_ID   ID 327-16A Location identifier
SAMP_TOP m 2DP 24.55 Depth to top of sample
SAMP_REF   X 24 Sample reference
SAMP_TYPE   PA U Sample type
SAMP_ID   ID ABC121415010 Sample unique global identifier
SPEC_REF   X 1a Specimen reference
SPEC_DPTH m 2DP 24.55 Depth to top of test specimen
SPEC_DESC   X Grey slightly gravelly clay Specimen description
SPEC_PREP   X Prepared according to client instructions Details of specimen preparation including time between preparation and testing
LDEN_TYPE   PA LINEAR Type of test performed
LDEN_COND   PA Undisturbed Sample condition
LDEN_SMTY   PA BLOCK SAMPLE Type of sample
LDEN_MC % MC 57 Moisture content
LDEN_BDEN Mg/m3 2DP 1.66 Bulk density
LDEN_DDEN Mg/m3 2DP 1.06 Dry density
LDEN_REM   X   Remarks
LDEN_METH   X BS1377: Part 2: 1990: Clause 7.2 Test method
LDEN_LAB   X ACME Laboratories plc Name of testing laboratory/organisation
LDEN_CRED   X UKAS 0000 Accrediting body and reference number (when appropriate)
TEST_STAT   X Checked Test status
FILE_FSET   X FS10 Associated file reference (eg test result sheets)

Notes - 1

  • Measurements of density on rock materials should be reported in RDEN.