| LOCA_ID |  | ID | 327-16A | Location identifier | 
|---|
| SAMP_TOP | m | 2DP | 24.55 | Depth to top of sample | 
|---|
| SAMP_REF |  | X | 24 | Sample reference | 
|---|
| SAMP_TYPE |  | PA | U | Sample type | 
|---|
| SAMP_ID |  | ID | ABC121415010 | Sample unique global identifier | 
|---|
| SPEC_REF |  | X | 1a | Specimen reference | 
|---|
| SPEC_DPTH | m | 2DP | 24.55 | Depth to top of test specimen | 
|---|
| SPEC_DESC |  | X | Grey slightly gravelly clay | Specimen description | 
|---|
| SPEC_PREP |  | X | Prepared according to client instructions | Details of specimen preparation including time between preparation and testing | 
|---|
| LSLT_SLIM | % | 2SF | 17 | Shrinkage limit | 
|---|
| LSLT_SHRA |  | 0DP |  | Shrinkage ratio | 
|---|
| LSLT_IDEN | Mg/m3 | 2DP | 1.66 | Initial density | 
|---|
| LSLT_MCI | % | MC | 20 | Initial moisture content of test specimen | 
|---|
| LSLT_425 | % | 0DP | 12 | Percentage passing 425? sieve | 
|---|
| LSLT_REM |  | X |  | Remarks | 
|---|
| LSLT_METH |  | X | BS1377: Part 2: 1990: Clause 6.3 | Test method | 
|---|
| LSLT_LAB |  | X | ACME Laboratories plc | Name of testing laboratory/organisation | 
|---|
| LSLT_CRED |  | X | UKAS 0000 | Accrediting body and reference number (when appropriate) | 
|---|
| TEST_STAT |  | X | Checked | Test status | 
|---|
| FILE_FSET |  | X | FS10 | Associated file reference (eg test result sheets) | 
|---|