| LOCA_ID |
|
ID |
327-16A |
Location identifier |
| DPRG_TESN |
|
X |
1 |
Test reference |
| DPRG_DATE |
yyyy-mm-dd |
DT |
20/03/2003 |
Test date |
| DPRG_TYPE |
|
PA |
DPL |
Dynamic probe type |
| DPRG_METH |
|
X |
BS EN ISO 22476-2 |
Test method |
| DPRG_MASS |
kg |
0DP |
50 |
Hammer mass |
| DPRG_DROP |
mm |
0DP |
500 |
Standard drop |
| DPRG_CONE |
mm |
0DP |
43 |
Cone base diameter |
| DPRG_ROD |
mm |
0DP |
35 |
Rod diameter |
| DPRG_TANV |
|
X |
|
Type of anvil |
| DPRG_DAMP |
|
X |
None |
Type of anvil damper |
| DPRG_TIP |
m |
2DP |
8 |
Depth of cone if left in ground |
| DPRG_REM |
|
X |
Hole backfilled on completion |
General remarks |
| DPRG_ANG |
deg |
0DP |
90 |
Cone angle |
| DPRG_RMSS |
kg/m |
1DP |
9 |
Rod mass |
| DPRG_PARF |
|
X |
|
Precautions against rod friction |
| DPRG_PDIU |
|
X |
|
Pre-drilling if used |
| DPRG_BCF |
|
X |
|
Blow count frequency |
| DPRG_GW |
m |
2DP |
1 |
Groundwater level |
| DPRG_REET |
|
X |
|
Reasons for early end of test |
| DPRG_ENV |
|
X |
Heavy rain |
Details of weather and environmental conditions during test |
| DPRG_CONT |
|
X |
ACME On-site Testing Ltd |
Name of testing organisation |
| DPRG_CRED |
|
X |
UKAS 0000 |
Accrediting body and reference number (when appropriate) |
| TEST_STAT |
|
X |
Checked |
Test status |
| FILE_FSET |
|
X |
FS25 |
Associated file reference (eg equipment calibrations) |