SCDT: Static Cone Dissipation Tests - Data

  • Class: Samples, Amalgamated Specimens and Laboratory Test Scheduling
Heading Unit Type Example Description
LOCA_ID   ID 327-16A Location identifier
SCPG_TESN   X 3 Test reference or push number
SCDG_DPTH m 2DP 5.2 Depth of dissipation test
SCDT_SECS s 0DP 50 Seconds elapsed since start of test
SCDT_RES MPa 3DP 0.801 Cone resistance
SCDT_PWP1 MPa 4DP   Face porewater pressure (u1)
SCDT_PWP2 MPa 4DP 0.0814 Shoulder porewater pressure (u2)
SCDT_PWP3 MPa 4DP   Top of sleeve porewater pressure (u3)
SCDT_REM   X   Comments
FILE_FSET   X FS19 Associated file reference (eg test result sheets)

Notes - 1

  • SCDT is used to include the dissipation test readings converted from the measurement data using any required calibration factors.