LOCA_ID |
|
ID |
327-16A |
Location identifier |
IPRG_TOP |
m |
2DP |
12.2 |
Depth to top of test zone |
IPRG_TESN |
|
X |
2 |
Test reference |
IPRG_BASE |
m |
2DP |
12.95 |
Depth to base of test zone |
IPRG_STG |
|
0DP |
1 |
Stage number of multistage packer test |
IPRG_TYPE |
|
PA |
Constant Head |
Type of test |
IPRG_PRWL |
m |
2DP |
10.6 |
Depth to water in borehole or piezometer immediately prior to test |
IPRG_SWAL |
m |
2DP |
5.4 |
Depth to water at start of test |
IPRG_TDIA |
m |
2DP |
0.15 |
Diameter of test zone |
IPRG_SDIA |
m |
3DP |
0.019 |
Diameter of standpipe or casing |
IPRG_IPRM |
m/s |
1SCI |
5.10E-09 |
Permeability |
IPRG_FLOW |
l/s |
1DP |
2.3 |
Average flow during packer test stage |
IPRG_AWL |
m |
2DP |
10 |
Depth to assumed standing water level |
IPRG_HEAD |
m |
2DP |
20.5 |
Applied total head of water during test stage at centre of packer test zone |
IPRG_DATE |
yyyy-mm-dd |
DT |
23/01/2008 |
Test date |
IPRG_REM |
|
X |
|
Test remarks |
IPRG_ENV |
|
X |
Sunny and warm |
Details of weather and environmental conditions during test |
IPRG_METH |
|
X |
BS5930 |
Test method |
IPRG_CONT |
|
X |
ACME On-site Testing Ltd |
Name of testing organisation |
IPRG_CRED |
|
X |
UKAS 0000 |
Accrediting body and reference number (when appropriate) |
TEST_STAT |
|
X |
Checked |
Test status |
FILE_FSET |
|
X |
FS26 |
Associated file reference (eg equipment calibrations) |