| LOCA_ID |  | ID | 327-16A | Location identifier | 
|---|
| IPRG_TOP | m | 2DP | 12.2 | Depth to top of test zone | 
|---|
| IPRG_TESN |  | X | 2 | Test reference | 
|---|
| IPRG_BASE | m | 2DP | 12.95 | Depth to base of test zone | 
|---|
| IPRG_STG |  | 0DP | 1 | Stage number of multistage packer test | 
|---|
| IPRG_TYPE |  | PA | Constant Head | Type of test | 
|---|
| IPRG_PRWL | m | 2DP | 10.6 | Depth to water in borehole or piezometer immediately prior to test | 
|---|
| IPRG_SWAL | m | 2DP | 5.4 | Depth to water at start of test | 
|---|
| IPRG_TDIA | m | 2DP | 0.15 | Diameter of test zone | 
|---|
| IPRG_SDIA | m | 3DP | 0.019 | Diameter of standpipe or casing | 
|---|
| IPRG_IPRM | m/s | 1SCI | 5.10E-09 | Permeability | 
|---|
| IPRG_FLOW | l/s | 1DP | 2.3 | Average flow during packer test stage | 
|---|
| IPRG_AWL | m | 2DP | 10 | Depth to assumed standing water level | 
|---|
| IPRG_HEAD | m | 2DP | 20.5 | Applied total head of water during test stage at centre of packer test zone | 
|---|
| IPRG_DATE | yyyy-mm-dd | DT | 23/01/2008 | Test date | 
|---|
| IPRG_REM |  | X |  | Test remarks | 
|---|
| IPRG_ENV |  | X | Sunny and warm | Details of weather and environmental conditions during test | 
|---|
| IPRG_METH |  | X | BS5930 | Test method | 
|---|
| IPRG_CONT |  | X | ACME On-site Testing Ltd | Name of testing organisation | 
|---|
| IPRG_CRED |  | X | UKAS 0000 | Accrediting body and reference number (when appropriate) | 
|---|
| TEST_STAT |  | X | Checked | Test status | 
|---|
| FILE_FSET |  | X | FS26 | Associated file reference (eg equipment calibrations) | 
|---|