LOCA_ID |
|
ID |
327-16A |
Location identifier |
IRES_DPTH |
m |
2DP |
1 |
Depth to which in situ resistivity test relates |
IRES_TESN |
|
X |
1 |
Test reference |
IRES_BASE |
m |
2DP |
2 |
Base depth to which in-situ resistivity test relates |
IRES_TYPE |
|
PA |
SCHL |
Type of resistivity test |
IRES_DATE |
yyyy-mm-dd |
DT |
20/03/2003 |
Test date |
IRES_IRES |
ohm m |
2SF |
2500 |
Mean value of the apparent resistivity |
IRES_RES1 |
ohm m |
2SF |
30 |
First value of apparent resistivity when more than 15% different to mean |
IRES_RES2 |
ohm m |
2SF |
10 |
Second value of apparent resistivity when more than 15% different to mean |
IRES_REM |
|
X |
|
Details of test eg. electrode spacing and configuration |
IRES_ENV |
|
X |
Misty and cold |
Details of weather and environmental conditions during test |
IRES_METH |
|
X |
BS1377: Part 9 |
Test method |
IRES_CONT |
|
X |
ACME On-site Testing Ltd |
Name of testing organisation |
IRES_CRED |
|
X |
UKAS 0000 |
Accrediting body and reference number (when appropriate) |
TEST_STAT |
|
X |
Checked |
Test status |
GEOL_STAT |
|
X |
1 |
Stratum reference shown on trial pit or traverse sketch |
FILE_FSET |
|
X |
FS26 |
Associated file reference (eg test result sheets) |